Free DISA STIG and SRG Library | Vaulted

CISC-L2-000100

The Cisco switch must have BPDU Guard enabled on all user-facing or untrusted access switch ports.

Finding ID
CISC-L2-000100
Rule ID
CISC-L2-000100_rule
Severity
Cat II
CCE
(None)
Group Title
SRG-NET-000362-L2S-000022
CCI
CCI-002385
Target Key
(None)
Documentable
No
Discussion

If a rogue switch is introduced into the topology and transmits a Bridge Protocol Data Unit (BPDU) with a lower bridge priority than the existing root bridge, it will become the new root bridge and cause a topology change, rendering the network in a suboptimal state. The STP PortFast BPDU guard enhancement allows network designers to enforce the STP domain borders and keep the active topology predictable. The devices behind the ports that have STP PortFast enabled are not able to influence the STP topology. At the reception of BPDUs, the BPDU guard operation disables the port that has PortFast configured. The BPDU guard transitions the port into errdisable state and sends a log message.

Fix Text

Ensure that BPDU Guard is enabled on all user-facing or untrusted access switch ports as shown in the configuration example below: SW1(config)#int range g0/0 - 9 SW1(config-if-range)#spanning-tree bpduguard enable Note: BPDU guard can also be enabled globally on all Port Fast-enabled ports by using the spanning-tree portfast bpduguard default command.

Check Content

Review the switch configuration to verify that BPDU Guard is enabled on all user-facing or untrusted access switch ports as shown in the configuration example below: interface GigabitEthernet0/0 spanning-tree bpduguard enable ! interface GigabitEthernet0/1 spanning-tree bpduguard enable … … … interface GigabitEthernet0/9 spanning-tree bpduguard enable If the switch has not enabled BPDU Guard, this is a finding.